These instructions apply to the installation of the Rexroth proportional valve interface board, model VSPA1-1, when used with Rexroth proportional valves DBET-6_ or DBET-5_.
Notice 1:
The Rexroth proportional valve interface board model VT2000 is obsolete, replaced by model VSPA1-1.
The VT2000 interface board can not be used with a DBET-6_ proportional valve.
 |
Legend
A. | DBET-5_ proportional valve | B. | DBET-6_ proportional valve | C. | VSPA1-1 interface board | 96RH708A06 | D. | Switch S1 | E. | Switch S2 |
|
DBET-5x Valves
The maximum output amperage is 0.8 amps. Set the switches as detailed below:
0.8 Amps Output
|
| Switch S2 | Switch S1 |
1 | OFF | OFF |
2 | OFF | OFF |
3 | OFF | OFF |
4 | OFF | OFF |
5 | OFF | OFF |
6 | ON | OFF |
7 | ON | ON |
DBET-6x Valves
The maximum output amperage is 1.6 amps. Set all the switches on the interface board to the OFF position.
1.6 Amps Output
|
| Switch S2 | Switch S1 |
1 | OFF | OFF |
2 | OFF | OFF |
3 | OFF | OFF |
4 | OFF | OFF |
5 | OFF | OFF |
6 | OFF | OFF |
7 | OFF | OFF |