Some MilTouch controllers utilize one peripheral board. This board contains all of the inputs, outputs, A to D, and D to A channels a washer needs. This is the 08BHF120 series of boards. This includes 08BHF120AT, 08BHF120BT, and 08BHF120CT boards.
08BHF120AT
This is the first iteration of the board series. This has been superseded by the 08BHF120BT.
08BHF120BT
This board introduced an onboard A to D channel for detecting out of balance loads for extract speed limiting. The previous version used Exact Extract, utilizing an accelerometer and balance board, to determine the magnitude of the imbalance. The BT version of the board receives a signal from the Yaskawa inverter on the A to D channel to detect the magnitude of imbalance. The Yaskawa inverter must have proprietary software installed to be able to use this function.
08BHF120CT
This board adds a new function for a 24V flowmeter to measure water consumption in the machine.
Outputs
Looking at the output indicator lights on this board, we see we have O-0 through O-29 grouped in rows of eight.
Indicator Light Number | Function | Contacts | Contacts |
---|
O-0 | Chemical 1 | N/O M2-1 | COM M2-10 |
O-1 | Chemical 2 | N/O M2-2 | COM M2-10 |
O-2 | Chemical 3 | N/O M2-3 | COM M2-10 |
O-3 | Chemical 4 | N/O M2-4 | COM M2-10 |
O-4 | Chemical 5 | N/O M2-5 | COM M2-10 |
O-5 | Chemical 6 | N/O M2-6 | COM M2-10 |
O-6 | Chemical 7 | N/O M2-7 | COM M2-10 |
O-7 | Chemical 8 | N/O M2-8 | COM M2-10 |
O-8 | Hot Water | N/O M3-1 | COM M3-15 |
O-9 | Cold Water | N/O M3-2 | COM M3-15 |
O-10 | Drain | N/O M3-3 | COM M3-15 |
O-11 | Flush | N/O M3-4 | COM M3-15 |
O-12 | Cooldown | N/O M3-5 | COM M3-15 |
O-13 | 3rd Water | N/O M3-6 | COM M3-15 |
O-14 | Reuse Drain | N/O M3-7 | COM M3-15 |
O-15 | Steam | N/O M3-8 | COM M3-15 |
O-16 | Door Lock | Independent Output | M3-10 M3-12 |
O-17 | Door Unlock (Pulse Door) Speed Limited (Non-Pulse Door) | Independent Output | M4-4 & M4-5 (Pulse Door) M3-9 & M3-14 (Non-Pulse Door) |
O-18 | Buzzer | Independent Output | M4-1 M4-2 |
O-19 | Door Unlock (Non-Pulse Door) Speed Limited (Pulse Door) | Independent Output | M4-4 & M4-5 (Non-Pulse Door) M3-9 & M3-14 (Pulse Door) |
O-20 | Alternate Deceleration Safety | Independent Output | M4-7 M4-8 |
O-21 | Formula in Progress | Independent Output | M4-18 M4-17 |
O-22 | Machine to Tank | Independent Output | M4-15 M4-14 |
O-23 | Machine to Machine | Independent Output | M4-12 M4-11 |
O-24 | Inverter Signal - S1 | N/O M5-1 | COM M5-8 |
O-25 | Inverter Signal - S2 | N/O M5-2 | COM M5-8 |
O-26 | Inverter Signal - S3 | N/O M5-3 | COM M5-8 |
O-27 | Inverter Signal - S4 | N/O M5-4 | COM M5-8 |
O-28 | Inverter Signal - S5 | N/O M5-5 | COM M5-8 |
O-29 | Inverter Signal - S6 | N/O M5-6 | COM M5-8 |
Inputs
Indicator Light Number | Function | Contact |
---|
IN-0 | Door Locked | M6-1 |
IN-1 | Low Level | M6-2 |
IN-2 | High Level | M6-3 |
IN-3 | Vibration Switch | M6-4 |
IN-4 | Inverter | M6-5 |
IN-5 | Door Open Desired | M6-6 |
IN-6 | Brake Off | M6-11 |
IN-7 | Fill Machine | M6-12 |
IN-8 | Timer Stop | M7-6 |
IN-9 | Front Not Down | M7-7 |
IN-10 | Speed Limit | M7-13 |
IN-11 | Bearing Seal | M7-14 |
IN-12 | N/A | N/A |
IN-13 | N/A | N/A |
IN-14 | N/A | N/A |
IN-15 | N/A | N/A |
IN-16 | N/A | N/A |
IN-17 | N/A | N/A |
IN-18 | N/A | N/A |
IN-19 | N/A | N/A |
IN-20 | N/A | N/A |
IN-21 | N/A | N/A |
IN-22 | N/A | N/A |
IN-23 | N/A | N/A |