This document contains a list of typical I/O for the 08BHF120 series of boards.
Some MilTouch controllers utilize one peripheral board. This board contains all of the inputs, outputs, A to D, and D to A channels a washer needs. This is the 08BHF120 series of boards.  This includes 08BHF120AT, 08BHF120BT, and 08BHF120CT boards.

08BHF120AT

This is the first iteration of the board series. This has been superseded by the 08BHF120BT.

08BHF120BT

This board introduced an onboard A to D channel for detecting out of balance loads for extract speed limiting. The previous version used Exact Extract, utilizing an accelerometer and balance board, to determine the magnitude of the imbalance. The BT version of the board receives a signal from the Yaskawa inverter on the A to D channel to detect the magnitude of imbalance. The Yaskawa inverter must have proprietary software installed to be able to use this function.

08BHF120CT

This board adds a new function for a 24V flowmeter to measure water consumption in the machine.

Outputs

08BHF120 Outputs
Looking at the output indicator lights on this board, we see we have O-0 through O-29 grouped in rows of eight.
Indicator Light NumberFunctionContactsContacts
O-0Chemical 1N/O M2-1COM M2-10
O-1Chemical 2N/O M2-2COM M2-10
O-2Chemical 3N/O M2-3COM M2-10
O-3Chemical 4N/O M2-4COM M2-10
O-4Chemical 5N/O M2-5COM M2-10
O-5Chemical 6N/O M2-6COM M2-10
O-6Chemical 7N/O M2-7COM M2-10
O-7Chemical 8N/O M2-8COM M2-10
O-8Hot WaterN/O M3-1COM M3-15
O-9Cold WaterN/O M3-2COM M3-15
O-10DrainN/O M3-3COM M3-15
O-11FlushN/O M3-4COM M3-15
O-12CooldownN/O M3-5COM M3-15
O-133rd WaterN/O M3-6COM M3-15
O-14Reuse DrainN/O M3-7COM M3-15
O-15SteamN/O M3-8COM M3-15
O-16Door LockIndependent OutputM3-10
M3-12
O-17Door Unlock (Pulse Door)
Speed Limited (Non-Pulse Door)
Independent OutputM4-4 & M4-5 (Pulse Door)
M3-9 & M3-14 (Non-Pulse Door)
O-18BuzzerIndependent OutputM4-1
M4-2
O-19Door Unlock (Non-Pulse Door)
Speed Limited (Pulse Door)
Independent OutputM4-4 & M4-5 (Non-Pulse Door)
M3-9 & M3-14 (Pulse Door)
O-20Alternate Deceleration SafetyIndependent OutputM4-7
M4-8
O-21Formula in ProgressIndependent OutputM4-18
M4-17
O-22Machine to TankIndependent OutputM4-15
M4-14
O-23Machine to MachineIndependent OutputM4-12
M4-11
O-24Inverter Signal - S1N/O M5-1COM M5-8
O-25Inverter Signal - S2N/O M5-2COM M5-8
O-26Inverter Signal - S3N/O M5-3COM M5-8
O-27Inverter Signal - S4N/O M5-4COM M5-8
O-28Inverter Signal - S5N/O M5-5COM M5-8
O-29Inverter Signal - S6N/O M5-6COM M5-8

Inputs

08BHF120 Inputs
Indicator Light NumberFunctionContact
IN-0Door LockedM6-1
IN-1Low LevelM6-2
IN-2High LevelM6-3
IN-3Vibration SwitchM6-4
IN-4InverterM6-5
IN-5Door Open DesiredM6-6
IN-6Brake OffM6-11
IN-7Fill MachineM6-12
IN-8Timer StopM7-6
IN-9Front Not DownM7-7
IN-10Speed LimitM7-13
IN-11Bearing SealM7-14
IN-12N/AN/A
IN-13N/AN/A
IN-14N/AN/A
IN-15N/AN/A
IN-16N/AN/A
IN-17N/AN/A
IN-18N/AN/A
IN-19N/AN/A
IN-20N/AN/A
IN-21N/AN/A
IN-22N/AN/A
IN-23N/AN/A
 
 
 

Feedback

 